Sensors

The Strain Gauge block represents a sensor that generates a change in resistance as a function of strain using the following equation:
![]()
where:
ΔR/R is the fractional change in resistance.
is the strain
at port B.
K is the Gauge factor parameter value.

The unstressed gauge resistance. The default value is 100 Ω.
The ratio K of the fractional change in resistance to the fractional change in length. The default value is 2.
The block has the following ports: