Products & Services Solutions Academia Support User Community Company

Learn more about SimHydraulics   

Constant Head Tank - Simulate tank where pressurization and fluid level remain constant regardless of volume change

Library

Low-Pressure Blocks

Description

The Constant Head Tank block represents a pressurized hydraulic reservoir, in which fluid is stored under a specified pressure. The size of the tank is assumed to be large enough to neglect the pressurization and fluid level change due to fluid volume. The block accounts for the fluid level elevation with respect to the tank bottom, as well as for pressure loss in the connecting pipe that can be caused by a filter, fittings, or some other local resistance. The loss is specified with the pressure loss coefficient. The block computes the volume of fluid in the tank and exports it outside through the physical signal port V.

The fluid volume value does not affect the results of simulation. It is introduced merely for information purposes. It is possible for the fluid volume to become negative during simulation, which signals that the fluid volume is not enough for the proper operation of the system. By viewing the results of the simulation, you can determine the extent of the fluid shortage.

The pressure at the tank inlet is computed with the following equations:

where

pPressure at the tank inlet
pelevPressure due to fluid level
plossPressure loss in the connecting pipe
pprPressurization
ρFluid density
gAcceleration of gravity
HFluid level with respect to the bottom of the tank
KPressure loss coefficient
ApConnecting pipe area
dConnecting pipe diameter
qFlow rate

Connection T is a hydraulic conserving port associated with the tank inlet. Connection V is a physical signal port. The flow rate is considered positive if it flows out of the tank.

Dialog Box and Parameters

Pressurization

Gage pressure acting on the surface of the fluid in the tank. It can be created by a gas cushion, membrane, bladder, or piston, as in bootstrap reservoirs. This parameter must be greater than or equal to zero. The default value is 0, which corresponds to a tank connected to atmosphere.

Fluid level

The fluid level with respect to the tank bottom. This parameter must be greater than zero. The default value is 1 m.

Initial fluid volume

The initial volume of fluid in the tank. This parameter must be greater than zero. The default value is 0.2 m^3.

Inlet pipeline diameter

The diameter of the connecting pipe. This parameter must be greater than zero. The default value is 0.02 m.

Pipeline pressure loss coefficient

The value of the pressure loss coefficient, to account for pressure loss in the connecting pipe. This parameter must be greater than zero. The default value is 1.2.

For reasons of computational robustness, the loss is computed with the equation similar to that used in the Fixed Orifice block:

The Critical Reynolds number is set to 15.

Ports

The block has the following ports:

T

Hydraulic conserving port associated with the tank inlet.

V

Physical signal port that outputs the volume of fluid in the tank.

See Also

Reservoir

Variable Head Tank

  


Related Products & Applications

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.

 © 1984-2009- The MathWorks, Inc.    -   Site Help   -   Patents   -   Trademarks   -   Privacy Policy   -   Preventing Piracy   -   RSS