Elements
The Parallel RLC Branch block implements a single resistor, inductor, and capacitor or a parallel combination of these. Use the Branch type parameter to select elements you want to include in the branch. If you eliminate either the resistance, inductance, or capacitance of the branch, the R, L, and C values are automatically set respectively to infinity (inf), infinity (inf), and 0 and the corresponding parameters no longer appear in the block dialog box. Only existing elements are displayed in the block icon.
Negative values are allowed for resistance, inductance, and capacitance.

Select the elements you want to include in the branch. The R letter defines the resistor, the L letter defines the inductor, and the C letter defines the capacitor. Select Open circuit to define an open circuit (R=inf, L=inf, C=0).
The branch resistance, in ohms (Ω). The Resistance parameter is not visible if the resistor element is not specified in the Branch type parameter.
The branch inductance, in henries (H). The Inductance parameter is not visible if the inductor element is not specified in the Branch type parameter.
If selected, the initial inductor current is defined by the Inductor initial current parameter. If not selected, the software calculates the initial inductor current in order to start the simulation steady-state.
The Set the initial inductor current parameter is not visible and have no effect on the block if the inductor element is not specified in the Branch type parameter.
The initial inductor current used at the start of the simulation. The Inductor initial current parameter is not visible and have no effect on the block if the inductor is not modeled and if the Set the initial inductor current parameter is not selected.
The branch capacitance, in farads (F). The Capacitance parameter is not visible if the capacitance element is not specified in the Branch type parameter.
If selected, the initial capacitor voltage is defined by the Capacitor initial voltage parameter. If not selected, the software calculates the initial capacitor voltage in order to start the simulation in steady-state.
The Set the initial capacitor voltage parameter is not visible and have no effect on the block if the capacitor element is not specified in the Branch type parameter.
The initial capacitor voltage used at the start of the simulation. The Capacitor initial voltage parameter is not visible and have no effect on the block if the capacitor is not modeled and if the Set the initial capacitor voltage parameter is not selected.
Select Branch voltage to measure the voltage across the Parallel RLC Branch block terminals.
Select Branch current to measure the total current (sum of R, L, C currents) flowing through the Parallel RLC Branch block.
Select Branch voltage and current to measure the voltage and the current of the Parallel RLC Branch block.
Place a Multimeter block in your model to display the selected measurements during the simulation. In the Available Measurements list box of the Multimeter block, the measurement is identified by a label followed by the block name.
Measurement | Label |
|---|---|
Branch voltage | Ub: |
Branch current | Ib: |
The power_paralbranch demo is used to obtain the frequency response of an eleventh-harmonic filter (tuned frequency at 660 Hz) connected on a 60 Hz power system:

The network impedance in the Laplace domain is
![]()
To obtain the frequency response of the impedance you have to get the state-space model (A B C D matrices) of the system.
This system is a one input (Is) and one output (Vs) system.
Note If you have Control System Toolbox software installed, you can get the transfer function Z(s) from the state-space matrices and the bode function. [A,B,C,D] = power_analyze('power_paralbranch');
freq = logspace(1,4,500);
w = 2*pi*freq;
[Zmag,Zphase] = bode(A,B,C,D,1,w);
subplot(2,1,1)
loglog(freq,Zmag)
grid
title('11th harmonic filter')
xlabel('Frequency, Hz')
ylabel('Impedance Z')
subplot(2,1,2)
semilogx(freq,Zphase)
xlabel('Frequency, Hz')
ylabel('phase Z')
grid
You can also use the Impedance Measurement block and the Powergui block to plot the impedance as a function of frequency. |

Multimeter, Parallel RLC Load, Powergui, Series RLC Branch, Series RLC Load