| Simulink® | ![]() |
Signal Routing

The Data Store Write block copies the value at its input to the named data store.
Each write operation performed by a Data Store Write block writes over the data store, replacing the previous contents.
The data store to which this block writes is determined by the location of the Data Store Memory or signal object that defines the data store. For more information, see Working with Data Stores and Data Store Memory. The size of the data store is set by the signal object or the Data Store Memory block that defines and initializes the data store. Each Data Store Write block that writes to that data store must write the same amount of data.
More than one Data Store Write block can write to the same data store. However, if two Data Store Write blocks attempt to write to the same data store during the same simulation step, results are unpredictable.
The Data Store Write block accepts a real or complex signal of any data type supported by Simulink software, including fixed-point and enumerated data types.
For a discussion on the data types supported by Simulink software, see Data Types Supported by Simulink.

Specifies the name of the data store to which this block writes data. The adjacent pull-down list lists the names of Data Store Memory blocks that exist at the same level in the model as the Data Store Write block or at higher levels. To change the name, select a name from the pull-down list or enter the name directly in the edit field.
When Simulink software compiles the model containing this block, Simulink software searches the model upwards from this block's level for a Data Store Memory block having the specified data store name. If Simulink software does not find such a block, it searches the model workspace and the MATLAB workspace for a Simulink.Signal object having the same name. If Simulink software finds the signal object, it creates a hidden Data Store Memory block at the model's root level having the properties specified by the signal object and an initial value of 0. If Simulink software finds neither the Data Store Memory block nor the signal object, it halts the compilation and displays an error.
This field lists the Data Store Memory block that initialized the store to which this block writes.
This parameter lists all the Data Store Read blocks with the same data store name as this block that are in the same (sub)system or in any subsystem below it in the model hierarchy. Double-click any entry on this list to highlight the block and bring it to the foreground.
Specify the sample time that controls when the block writes to the data store. A value of -1 indicates that the sample time is inherited. See Specifying Sample Time in the online documentation for more information.
Sample Time | Specified in the Sample time parameter |
Dimensionalized | Yes |
Multidimensionalized | Yes |
Data Store Memory, Data Store Read
![]() | Data Store Read | Data Type Conversion | ![]() |
| © 1984-2008- The MathWorks, Inc. - Site Help - Patents - Trademarks - Privacy Policy - Preventing Piracy - RSS |