Discontinuities

The Relay block allows its output to switch between two specified values. When the relay is on, it remains on until the input drops below the value of the Switch off point parameter. When the relay is off, it remains off until the input exceeds the value of the Switch on point parameter. The block accepts one input and generates one output.
The Switch on point value must be greater than or equal to the Switch off point. Specifying a Switch on point value greater than the Switch off point value models hysteresis, whereas specifying equal values models a switch with a threshold at that value.
Note When the initial input falls between the Switch off point and Switch on point values, the initial output is the value when the relay is off. |
The Relay block accepts signals of the following data types:
Floating-point
Built-in integer
Fixed-point
Boolean
For more information, see Data Types Supported by Simulink in the Simulink documentation.
The Main pane of the Relay block dialog box appears as follows:

The "on" threshold for the relay. The Switch on point parameter is converted to the input data type offline using round-to-nearest and saturation.
The "off" threshold for the relay. The Switch off point parameter is converted to the input data type offline using round-to-nearest and saturation.
The output when the relay is on.
The output when the relay is off.
Select to enable zero-crossing detection. For more information, see Zero-Crossing Detection.
Specify the time interval between samples. To inherit the sample time, set this parameter to -1. See How to Specify the Sample Time in the Simulink documentation for more information.
The Signal Attributes pane of the Relay block dialog box appears as follows:

Specify the minimum value that the block should output. The default value, [], is equivalent to -Inf. Simulink software uses this value to perform:
Parameter range checking (see Checking Parameter Values)
Simulation range checking (see Checking Signal Ranges)
Automatic scaling of fixed-point data types
Specify the maximum value that the block should output. The default value, [], is equivalent to Inf. Simulink software uses this value to perform:
Parameter range checking (see Checking Parameter Values)
Simulation range checking (see Checking Signal Ranges)
Automatic scaling of fixed-point data types
Specify the output data type. You can set it to:
A rule that inherits a data type, for example, Inherit: Inherit via back propagation
The name of a built-in data type, for example, single
The name of a data type object, for example, a Simulink.NumericType object
An expression that evaluates to a data type, for example, fixdt(1,16,0)
Click the Show data type assistant button
to display the Data
Type Assistant, which helps you set the Output
data type parameter.
See Specifying Block Output Data Types for more information.
Select to lock the output data type setting of this block against changes by the Fixed-Point Tool and the Fixed-Point Advisor. For more information, see Fixed-Point Tool and Fixed-Point Advisor in the Simulink Fixed Point documentation.
Direct Feedthrough | Yes |
Sample Time | Specified in the Sample time parameter |
Scalar Expansion | Yes |
Dimensionalized | Yes |
Zero-Crossing Detection | Yes, if enabled |