The Adaptive Lookup Table (nD Stair-Fit) block creates an adaptive lookup table of arbitrary dimension by dynamically updating the underlying lookup table. The block uses the outputs of your system to do the adaptations.
Each indexing parameter may take a value within a set of adapting data points, which are called breakpoints. Breakpoints in each dimension define a cell. The set of all breakpoints in one of the dimensions defines a grid. In the n-dimensional case, each cell has two n breakpoints and is an (n-1) hypersurface.
You can use the Adaptive Lookup Table (nD Stair-Fit) block to model time-varying systems with 2 or more inputs.
Doubles only

The number of dimensions for the adaptive lookup table.
A set of one-dimensional vectors that contains possible block input values for the input variables. Each input row must be monotonically increasing, but the rows do not have to be the same length. For example, if the Number of table dimensions is 3, you can set the table breakpoints as follows:
{[1 2 3], [5 7], [1 3 5 7]}
Selecting this check box forces the Adaptive Lookup Table (nD Stair-Fit) block to ignore the Table data (initial) parameter, and creates a new input port Tin. Use this port to input the table data.
The initial table output values. This (n-D) array must be of size (n-1)-by-(n-1) ... -by- (n-1), (D times), where D is the number of dimensions and n is the number of input breakpoints.
Number values assigned to cells. This vector must be the same size as the table data array, and each value must be unique.
Choose Sample mean or Sample mean with forgetting. Sample mean averages all the values received within a cell. Sample mean with forgetting gives more weight to the new data. How much weight is determined by the Adaptation gain parameter. For more information, see Selecting an Adaptation Method.
A number from 0 to 1 that regulates the weight given to new data during the adaptation. A 0 means short memory (last data becomes the table value), and 1 means long memory (average all data received in a cell).
Selecting this check box creates an additional output port Tout for the adapted table.
Selecting this check box creates an additional input port Enable that enables, disables, or resets the adaptive lookup table. A signal value of 0 applied to the port disables the adaptation, and signal value of 1 enables the adaptation. Setting the signal value to 2 resets the table values to the initial table data.
Selecting this check box creates an additional input port Lock that provides the means for updating only specified cells during a simulation run. A signal value of 0 unlocks the specified cells and signal value of 1 locks the specified cells.
Ignore or Adapt by extrapolating beyond the extreme breakpoints.
Adaptive Lookup Table (1D Stair-Fit), Adaptive Lookup Table (2D Stair-Fit), Capturing Time-Varying System Behavior Using Adaptive Lookup Tables