| Data Acquisition Toolbox | ![]() |
Specify the type of trigger to execute
Description
TriggerType can be Immediate, Manual, or Software. If TriggerType is Immediate, the trigger occurs immediately after the start function is issued. If TriggerType is Manual, the trigger occurs immediately after the trigger function is issued. If TriggerType is Software, the trigger occurs when the associated trigger condition is satisfied (AI only).
For a given hardware device, additional trigger types might be available. Some trigger types require trigger conditions and trigger condition values. Trigger conditions are specified with the TriggerCondition property, while trigger condition values are specified with the TriggerConditionValue property.
When a trigger occurs for an analog input object, data logging is initiated and the Logging property is automatically set to On. When a trigger occurs for an analog output object, data sending is initiated and the Sending property is automatically set to On.
Characteristics
| Usage |
AI, AO, Common |
| Access |
Read/write |
| Data type |
String |
| Read-only when running |
Yes |
All Supported Hardware
Agilent Technologies
Keithley
HwDigital |
The trigger source is an external digital signal (AI only). Pretrigger data cannot be captured. |
Measurement Computing
HwDigital |
The trigger source is an external digital signal (AI only). Pretrigger data cannot be captured. |
HwAnalog |
The trigger source is an external analog signal (AI only). |
National Instruments
For 1200 Series hardware, HwDigital is the only device-specific TriggerType value for analog input subsystems. Analog output subsystems do not support any device-specific TriggerType values.
Functions
Properties
Logging, Sending, TriggerCondition, TriggerConditionValue
| TriggersExecuted | Type | ![]() |
Learn more about the latest releases of MathWorks products: |
| © 1994-2009 The MathWorks, Inc. - Site Help - Patents - Trademarks - Privacy Policy - Preventing Piracy - RSS |