SimPowerSystems    
AC Current Source

Purpose

Implement a sinusoidal current source

Library

Electrical Sources

Description

The AC Current Source block implements an ideal AC current source. The positive current direction is indicated by the arrow in the block icon. The generated current I is described by the following relationship:

Negative values are allowed for amplitude and phase. A zero frequency specifies a DC current source. You cannot enter a negative frequency; Simulink returns an error in that case, and the block displays a question mark in the block icon. You can modify the first three block parameters at any time during the simulation.

Dialog Box and Parameters

Peak amplitude
The peak amplitude of the generated current, in amperes (A).
Phase
The phase in degrees (deg).
Frequency
The source frequency in hertz (Hz).
Sample time
The sample period in seconds (s). The default is 0, corresponding to a continuous source.
Measurements
Select Current to measure the current flowing through the AC Current Source block.
Place a Multimeter block in your model to display the selected measurements during the simulation. In the Available Measurements list box of the Multimeter block, the measurement is identified by a label followed by the block name.

Measurement
Label

Current

Isrc:

Example

The power_accurrent demo uses two AC Current Source blocks in parallel to sum two sinusoidal currents in a resistor.

See Also

Controlled Current Source, Multimeter