| SimPowerSystems | ![]() |
Implement a sinusoidal voltage source
Library
Description![]()
The AC Voltage Source block implements an ideal AC voltage source. The generated voltage U is described by the following relationship:
Negative values are allowed for amplitude and phase. A 0 frequency specifies a DC voltage source. Negative frequency is not allowed; otherwise Simulink signals an error, and the block displays a question mark in the block icon. You can modify the first three block parameters at any time during the simulation.
Dialog Box and Parameters
0, corresponding to a continuous source.Voltage to measure the voltage across the terminals of the AC Voltage Source block. | Measurement |
Label |
Example
The power_acvoltage demo uses two AC Voltage Source blocks at different frequencies connected in series across a resistor. The sum of the two voltages is read by a Voltage Measurement block.
See Also
Controlled Voltage Source, DC Voltage Source, Multimeter
| Active & Reactive Power | Asynchronous Machine | ![]() |
Learn more about the latest releases of MathWorks products: |
| © 1994-2009 The MathWorks, Inc. - Site Help - Patents - Trademarks - Privacy Policy - Preventing Piracy - RSS |