sparameters

S-parameter object

Syntax

sobj = sparameters(antenna,freq,Z0)
sobj = sparameters(array,freq,Z0)

Description

example

sobj = sparameters(antenna,freq,Z0) calculates the complex s-parameters for an antenna object over specified frequency values and for a given reference impedance, Z0.

example

sobj = sparameters(array,freq,Z0) calculates the complex s-parameters for an array object over specified frequency values and for a given reference impedance, Z0.

Examples

collapse all

Calculate the complex s-parameters for a default dipole at 70MHz frequency.

 h = dipole
h = 
  dipole with properties:

        Length: 2
         Width: 0.1000
    FeedOffset: 0
          Tilt: 0
      TiltAxis: [1 0 0]
          Load: [1x1 lumpedElement]

 sparameters (h, 70e6)
ans = 
  sparameters: S-parameters object

       NumPorts: 1
    Frequencies: 70000000
     Parameters: 0.2001 + 0.0037i
      Impedance: 50

  rfparam(obj,i,j) returns S-parameter Sij

Calculate the complex s-parameters for a default rectangular array at 70MHz frequency.

h = rectangularArray;
sparameters(h,70e6)
ans = 
  sparameters: S-parameters object

       NumPorts: 4
    Frequencies: 70000000
     Parameters: [4x4 double]
      Impedance: 50

  rfparam(obj,i,j) returns S-parameter Sij

Input Arguments

collapse all

Antenna object, specified as a scalar handle.

Array object, specified as a scalar handle.

S-parameter frequencies, specified as a vector of positive real numbers, sorted from smallest to largest.

Reference impedance in ohms, specified as a positive real scalar. You cannot specify Z0 if you are importing data from a file. The argument Z0 is optional and is stored in the Impedance property.

When making a deep copy of an S-parameter object, this input argument is not supported. To change the reference impedance of an S-parameters object, use newref.

Output Arguments

collapse all

S-parameter data, returned as a scalar handle. disp(hs) returns the properties of the object:

  • NumPorts — Number of ports, specified as an integer. The function calculates this value automatically when you create the object.

  • Frequencies — S-parameter frequencies, specified as a K-by-1 vector of positive real numbers sorted from smallest to largest. The function sets this property from the filename or freq input arguments.

  • Parameters — S-parameter data, specified as an N-by-N-by-K array of complex numbers. The function sets this property from the filename or data input arguments.

  • Impedance — Reference impedance in ohms, specified as a positive real scalar. The function sets this property from the filename or Z0 input arguments. If no reference impedance is provided, the function uses a default value of 50.