RBDS and RadioText Plus (RT+) FM Receiver

This example shows how you can use Simulink® and the Communications System Toolbox™ to extract program or song information from FM radio stations using the RBDS standard and, optionally, the RadioText Plus (RT+) standard. You can either use captured signals or receive signals in real time using the Communications System Toolbox Support Package for RTL-SDR Radio.

Required Hardware and Software

To run this example using captured signals, you need Simulink and the Communications System Toolbox™. To receive signals in real time, you need RTL-SDR radio hardware and the Communications System Toolbox Support Package for RTL-SDR Radio. For a full list of supported SDR platforms, refer to Supported Hardware section of Software Defined Radio (SDR) discovery page.

Background

RBDS and RDS are very similar standards specifying how to supplement FM radio signals with additional information. RBDS is used in North America, while RDS was originally used in Europe and evolved to an international standard. RBDS and RDS comprise 3 layers:

  • Physical layer (Layer 1)

  • Data-link layer (Layer 2)

  • Session and presentation layer (Layer 3)

Physical Layer (Layer 1)

The physical layer subsystem receives the captured signal from a file or the live signal from the radio and performs the following steps:

  • FM demodulation: Once the FM signal is demodulated, the RBDS signal resides at the 57 kHz +/- 2.4 kHz band:

Be aware that the RBDS signal is transmitted with relatively low power, so it is not always visible in the FM spectrum as in the above figure.

FM signals contain a pilot tone at 19 kHz, which can be used as a phase and frequency reference for coherent demodulation of the RBDS signal at 57 kHz and the stereo audio at 38 kHz. Pilot tones at 38 kHz and 57 kHz can be generated by doubling and tripling the frequency of the 19 kHz pilot tone [ 2 ].

Processing steps for coherent demodulation of the RBDS signal are:

  • Bandpass filtering: The PHY receiver conducts bandpass filtering at 19 kHz and 57 kHz, to isolate the pilot tone and the RBDS signal, respectively.

  • Frequency tripling: Raise the complex representation of the 19 kHz pilot tone to the 3rd power to triple its frequency and obtain a 57 kHz pilot tone.

  • AM Demodulation: RBDS symbols are generated at an 1187.5 Hz rate and are AM-modulated to a 57 kHz carrier. The 57 kHz RBDS signal can be coherently demodulated with a 57 kHz carrier that is locked in frequency and phase. Typically, the frequency-tripled 19 kHz pilot tone suffices for coherent demodulation. The next figures show the 19 kHz and 57 kHz pilot tones, the 57 kHz RBDS signal, and the AM-demodulated baseband RBDS signal.

At the same time, there exist several FM stations whose 57 kHz RBDS signal exhibits a time-varying phase offset from the 19 kHz pilot tone and its frequency-tripled version. The PHY receiver contains a Costas loop to compensate for such time-varying phase offsets.

  • Costas loop: The Costas loop performs 2 orthogonal AM demodulations, one demodulation with a 57 kHz sine and another with a 57 kHz cosine. The sampling rate of the received signal is carefully chosen as 228 kHz, which provides 4 samples per 57 kHz cycle. Therefore, a one sample delay of the 57 kHz pilot tone results to a one quarter wavelength phase offset, and allows us to generate a cosine wave from a sine wave. The sine-demodulated signal corresponds to the coherent demodulation output. The cosine-demodulated signal is used for detection of phase error. The products of the 57 kHz RBDS signal with the sine/cosine waves are low-pass filtered with the filter specified in Sec. 1.7 of [ 1 ]. The product of the two filter outputs is an error signal. The larger it is, the more the 19 kHz pilot tone is delayed to behave more like the cosine-based demodulator.

  • Clock extraction: To perform biphase symbol decoding, a clock matching the RBDS symbol rate of 1187.5 Hz is extracted from the 19 kHz pilot tone. Note, 1187.5 Hz x 16 = 19 kHz. To account for frequency offsets, frequency division is used to extract the clock from the 19 kHz pilot tone. Since the frequency division operation provides multiple correct answers, the baseband RBDS signal serves as training data that aid in the determination of the desired output.

  • Biphase symbol decoder: RBDS uses bi-phase-level (bi- -L) coding, which is commonly known as Manchester coding. In each clock cycle, the RBDS symbol takes two opposite amplitude values, either a positive followed by a negative, or a negative followed by a positive. The biphase symbol decoder negates the second amplitude level, so that each symbol holds the same amplitude level throughout the entire clock cycle. The new clock-wide amplitude level corresponds to the symbol's bit representation. The following two screenshots correspond to the waveforms #1-6 in Figure 2 of [ 1 ].

To obtain each symbol's bit value, the waveform is integrated over each clock cycle, and the outcome is compared to zero (slicer).

  • Differential decoding: Finally, the bits are differentially decoded to revert the differential encoding at the transmitter.

Data-link Layer (Layer 2)

Layer 2 is implemented using the RBDSDataLinkDecoder System block. This block is responsible for synchronization and error correction. The bit output of the PHY layer is logically organized in 104-bit groups comprising four 26-bit blocks. Each block contains a 16-bit information word and 10 parity bits (see Figure 8 in [ 1 ]). A distinct 10-bit offset word is modulo-2 added to the parity bits of each block.

  • Synchronization: Initially, block and group boundaries are sought exhaustively using a sliding window of 104 bits. For each 104-bit window, the 4 offset words are sought at the last 10 bits of each 26-bit block. An offset word is identified if no bit errors are detected in its block. Once the offset words are identified, group-level synchronization is attained and the exhaustive sliding-window processing stops. Subsequently, the next 104 bits will be treated as a separate group. If future groups contain bit errors and the offset words cannot be identified, synchronization may be lost. In this case, Layer 2 first examines the possibility of 1-bit synchronization slips, using the fact that the first information word (16 bits) is always the same for all bit groups. If the first information word is found dislocated by 1 bit, synchronization is retained and the group boundaries are updated accordingly. If bit errors persist for 25 group receptions, and in the meantime the first information word cannot be found dislocated by a single bit slip, then synchronization is lost and Layer 2 re-enters the exhaustive, sliding-window-based search for synchronization.

  • Error correction: The RBDS error correction code is a (26, 16) cyclic code shortened from (341, 331). The error correction implementation uses the shift-register scheme described in Annex B of [ 1 ].

Session and Presentation Layer (Layer 3)

Layer 2 removes the parity/offset bits, therefore Layer 3 receives groups of 64-bits, comprising four 16-bit blocks. There exist up to 32 different group types, each labeled with a number from 0 to 15 and the letter 'A' or 'B', for example, 0B, 2A, 3A. The format of each group can be fixed or it can be abstract if this group is allocated for an Open Data Application (ODA, see list in [ 3 ]).

Layer 3 is implemented using the RBDSSessionDecoder System block. This block supports decoding of the 0A, 0B, 2A, 2B, 3A, 4A, 10A fixed-format group types.

  • 0A and 0B convey an 8-character string, which typically changes in a scrolling-text fashion.

  • 2A and 2B convey longer 64- or 32-character strings.

  • 3A registers ODAs and specifies their dedicated abstract-format group type.

  • 4A conveys the system time.

  • 10A further categorizes the program type (e.g., 'Football' for 'Sports' program type).

For ODAs, the RBDS receiver supports decoding of RadioText Plus (RT+) [ 4 ]. This ODA can break down the long 32 or 64-character string from group types 2A and 2B into two specific content types (for example, artist and song).

Viewing Results

The following screenshot illustrates the graphical display of the processed RBDS data:

  • Basic RBDS information:

  1. The first field corresponds to the program type, which is conveyed by the second information word of all group types. If 10A group types are received, the first field also provides further characterization, e.g., Sports \ Football.

  2. The second field illustrates the 8-character text conveyed by 0A/0B groups.

  3. The third field illustrates the longer 32/64-character text conveyed by 2A/2B group types.

  • RadioText Plus (RT+): This section is used if any 3A groups indicate that the RadioText Plus (RT+) ODA [ 4 ] uses a certain abstract-format group type, e.g., 11A. Then, upon receptions of this abstract group type, the 32/64-character text conveyed by groups 2A/2B will be split to two substrings. Moreover, the two labels will be updated to characterize the substrings (e.g., Artist and Song).

  • Group type receptions: The tables act as a histogram illustrating which group types have been received from a station and with what frequency. As a result, users may want to look at the logged data for further information that is not depicted in the graphical viewer (e.g., system time in 4A, alternate frequencies in 0A etc.).

  • Open data applications (ODA): If any 3A group types are received, then the list of encountered ODAs is updated with the ODA name and their dedicated group type.

Moreover, you can enable the 'Log data to file' checkbox in order to log further fields from all group types.

Selected Bibliography

  1. National Radio Systems Committee, United States RBDS standard, April 1998

  2. Der, Lawrence. "Frequency Modulation (FM) Tutorial". Silicon Laboratories Inc.

  3. List of ODA Applications in RDS

  4. RadioText Plus (RT+) Specification

  5. Joseph P. Hoffbeck, "Teaching Communication Systems with Simulink and the USRP", ASEE Annual Conference, San Antonio, TX, June 2012