This is machine translation

Translated by Microsoft
Mouse over text to see original. Click the button below to return to the English verison of the page.

Numeric Model of SISO Feedback Loop

This example shows how to interconnect numeric LTI models representing multiple system components to build a single numeric model of a closed-loop system, using model arithmetic and interconnection commands.

Construct a model of the following single-loop control system.

The feedback loop includes a plant G(s), a controller C(s), and a representation of sensor dynamics, S(s). The system also includes a prefilter F(s).

  1. Create model objects representing each of the components.

    G = zpk([],[-1,-1],1);
    C = pid(2,1.3,0.3,0.5);
    S = tf(5,[1 4]);
    F = tf(1,[1 1]);

    The plant G is a zero-pole-gain (zpk) model with a double pole at s = –1. Model object C is a PID controller. The models F and S are transfer functions.

  2. Connect the controller and plant models.

    H = G*C;

    To combine models using the multiplication operator *, enter the models in reverse order compared to the block diagram.

      Tip   Alternatively, construct H(s) using the series command:

      H = series(C,G);
  3. Construct the unfiltered closed-loop response T(s)=H1+HS.

    T = feedback(H,S);

      Caution   Do not use model arithmetic to construct T algebraically:

      T = H/(1+H*S)

      This computation duplicates the poles of H, which inflates the model order and might lead to computational inaccuracy.

  4. Construct the entire closed-loop system response from r to y.

    T_ry = T*F;

T_ry is a Numeric LTI Model representing the aggregate closed-loop system. T_ry does not keep track of the coefficients of the components G, C, F, and S.

You can operate on T_ry with any Control System Toolbox™ control design or analysis commands.