Documentation

This is machine translation

Translated by Microsoft
Mouseover text to see original. Click the button below to return to the English verison of the page.

Note: This page has been translated by MathWorks. Please click here
To view all translated materals including this page, select Japan from the country navigator on the bottom of this page.

Simultaneously Acquire and Generate Periodic Waveforms using Digilent® Analog Discovery™

This example shows how to use the function generator channel to generate an 1 KHz sinusoidal waveform function and record data at the same time, using analog inputs. The output voltage-range of the outgoing signal is -5.0 to +5.0 volts. This example uses the session-based interface with Digilent Analog Discovery hardware.

Create a session with a Digilent device

Discover Digilent devices connected to your system using daq.getDevices and create a session using the listed Digilent device.

s = daq.createSession('digilent')
s = 

Data acquisition session using Digilent Inc. hardware:
   Will run for 1 second (10000 scans) at 10000 scans/second.
   No channels have been added.
   

Add a function generator channel

Add a function generator channel with device ID AD1 and channel ID 1. Set the waveform type to Sine.

fgenCh = addFunctionGeneratorChannel(s, 'AD1', 1, 'Sine')
fgenCh = 

Data acquisition sine waveform generator '1' on device 'AD1':

          Phase: 0
          Range: -5.0 to +5.0 Volts
 TerminalConfig: SingleEnded
           Gain: 1
         Offset: 0
      Frequency: 4096
   WaveformType: Sine
 FrequencyLimit: [0.0001 25000000.0]
           Name: ''
             ID: '1'
         Device: [1x1 daq.di.DeviceInfo]
MeasurementType: 'Sine'


Set channel properties

Set channel gain to 5 (sets the amplitude of the sinusoid to 5 V). Save the gain setting to a variable, in order to set axes.

gain = 5;
fgenCh.Gain = gain;

Set the frequency to 1 KHz

fgenCh.Frequency = 1000;

Add an analog input channel

Add an analog input channel with device ID AD1 and channel ID 1. Set the measurement type to Voltage.

aiCh = addAnalogInputChannel(s, 'AD1', 1, 'Voltage')
aiCh = 

Data acquisition analog input voltage channel '1' on device 'AD1':

       Coupling: DC
 TerminalConfig: Differential
          Range: -25 to +25 Volts
           Name: ''
             ID: '1'
         Device: [1x1 daq.di.DeviceInfo]
MeasurementType: 'Voltage'


Set Session properties

Acquire data at a higher rate than the highest frequency in the generated waveform. Set the duration of the generation to be 1 second.

s.Rate = 100 * fgenCh.Frequency;
s.DurationInSeconds = 1;

Generate continuous data and record input simultaneously

[data, timestamps] = startForeground(s);

Display the results

period = 1/fgenCh.Frequency;
plot(timestamps, data);
xlabel('Time in seconds'); ylabel('Voltage in volts');
title(['Period = ', num2str(period), ' seconds'])
axis([0 5*period -gain gain])

Was this topic helpful?