EnhancedAliasRejectionEnable

Set enhanced alias rejection mode

Description

Enable or disable the enhanced alias rejection on your DSA device's analog channel. See Synchronize DSA Devices for more information. Enhanced alias reject is disabled by default. This property only takes logical values.

s.Channels(1).EnhancedAliasRejectionEnable = 1

You cannot modify enhanced rejection mode if you are synchronizing your DSA device using AutoSyncDSA.

Example

Enable Enhanced Alias Rejection

Enable enhanced alias rejection on a DSA device.

Create a session and add an analog input voltage channel using a DSA device.

s = daq.createSession('ni');
ch = addAnalogInputChannel(s,'PXI1Slot2', 0, 'Voltage')
ch = 

Data acquisition analog input voltage channel 'ai0' on device 'PXI1Slot2':

                    Coupling: DC
              TerminalConfig: PseudoDifferential
                       Range: -42 to +42 Volts
                        Name: ''
                          ID: 'ai0'
                      Device: [1x1 daq.ni.PXIDSAModule]
             MeasurementType: 'Voltage'
EnhancedAliasRejectionEnable: 0

Enable enhanced alias rejection.

ch.EnhancedAliasRejectionEnable = 1
ch = 

Data acquisition analog input voltage channel 'ai0' on device 'PXI1Slot2':

                    Coupling: DC
              TerminalConfig: PseudoDifferential
                       Range: -42 to +42 Volts
                        Name: ''
                          ID: 'ai0'
                      Device: [1x1 daq.ni.PXIDSAModule]
             MeasurementType: 'Voltage'
EnhancedAliasRejectionEnable: 1