This is machine translation

Translated by Microsoft
Mouse over text to see original. Click the button below to return to the English verison of the page.


Resistance value of channel's shunt resistor


When working with the session-based interface, the analog input current channel's ShuntResistance property indicates resistance in ohms. This value is automatically set if the shunt resistor is located internally on the device and is read only.

    Note:   Before starting an analog output channel with an external shunt resistor, specify the shunt resistance value.


Specify Shunt Resistance

Set the shunt resistance of an analog input current channel.

Create a session and add an analog input current channel.

s = daq.createSession('ni')
ch = addAnalogInputChannel(s,'cDAQ1Mod7',0,'Current');

Set the ShuntLocation to External and the ShuntResistance to 20.

ch.ShuntLocation = 'External';
ch.ShuntResistance = 20
ch = 

Data acquisition analog input current channel 'ai0' on device 'cDAQ1Mod7':

  ShuntLocation: External
ShuntResistance: 20
       Coupling: DC
 TerminalConfig: Differential
          Range: -0.025 to +0.025 A
           Name: ''
             ID: 'ai0'
         Device: [1x1]
MeasurementType: 'Current'
  ADCTimingMode: HighResolution

See Also

Was this topic helpful?