Documentation Center

  • Trial Software
  • Product Updates

ZResetCondition

Reset condition for Z-indexing

Description

When working with the session-based interface, use the ZResetCondition property to specify reset conditions for Z-indexing of counter Input 'Position' channels. Accepted values are:

  • 'BothHigh'

  • 'BothLow'

  • 'AHigh'

  • 'BHigh'

Example

Change Counter Channel Z Reset Condition

Create a session and add a counter input Position channel.

s=daq.createSession('ni');
ch=addCounterInputChannel(s,'cDAQ1Mod5',0,'Position')
ch = 

Data acquisition counter input position channel 'ctr0' on device 'cDAQ1Mod5':

    EncoderType: X1
   ZResetEnable: 0
    ZResetValue: 0
ZResetCondition: BothHigh
      TerminalA: 'PFI0'
      TerminalB: 'PFI2'
      TerminalZ: 'PFI1'
           Name: ''
             ID: 'ctr0'
         Device: [1x1 daq.ni.CompactDAQModule]
MeasurementType: 'Position'

Change the ZResetCondition to BothLow.

ch.ZResetCondition='BothLow'
ch = 

Data acquisition counter input position channel 'ctr0' on device 'cDAQ1Mod5':

    EncoderType: X1
   ZResetEnable: 0
    ZResetValue: 0
ZResetCondition: BothLow
      TerminalA: 'PFI0'
      TerminalB: 'PFI2'
      TerminalZ: 'PFI1'
           Name: ''
             ID: 'ctr0'
         Device: [1x1 daq.ni.CompactDAQModule]
MeasurementType: 'Position'
Was this topic helpful?