Documentation

This is machine translation

Translated by Microsoft
Mouseover text to see original. Click the button below to return to the English verison of the page.

Note: This page has been translated by MathWorks. Please click here
To view all translated materals including this page, select Japan from the country navigator on the bottom of this page.

phased.IsotropicHydrophone System object

Isotropic hydrophone

Description

The phased.IsotropicHydrophone System object™ creates an isotropic hydrophone for sonar applications. An isotropic hydrophone has the same response in all signal directions. The response is the output voltage of the hydrophone per unit sound pressure. The response for a hydrophone is also call its sensitivity. You can specify the response using the VoltageSensitivity property.

To compute the response of a hydrophone for specified directions:

  1. Define and set up an isotropic hydrophone System object. See Construction.

  2. Call step to compute the response according to the properties of phased.IsotropicHydrophone.

Note

Instead of using the step method to perform the operation defined by the System object, you can call the object with arguments, as if it were a function. For example, y = step(obj,x) and y = obj(x) perform equivalent operations.

Construction

hydrophone = phased.IsotropicHydrophone creates a isotropic hydrophone System object, hydrophone.

hydrophone = phased.IsotropicHydrophone(Name,Value) creates an isotropic hydrophone System object, with each specified property Name set to the specified Value. You can specify additional name-value pair arguments in any order as (Name1,Value1,...,NameN,ValueN).

Properties

expand all

Operating frequency range of hydrophone, specified as a real-valued 1-by-2 row vector of the form [LowerBound HigherBound]. This property defines the frequency range over which the hydrophone has a response. The hydrophone element has zero response outside this frequency range. Units are in Hz.

Example: [0 1000]

Data Types: double

Voltage sensitivity of hydrophone, specified as a scalar or real-valued 1-by-K row vector. When you specify the voltage sensitivity as a scalar, that value applies to the entire frequency range specified by FrequencyRange. When you specify the voltage sensitivity as a vector, the frequency range is divided into K-1 equal intervals. The sensitivity values are assigned to the interval end points. The step method interpolates the voltage sensitivity for any frequency inside the frequency range. Units are in dB//1V/μPa. See Hydrophone Sensitivity for more details.

Example: 10

Data Types: double

Backbaffle hydrophone element, specified as false or true. Set this property to true to backbaffle the hydrophone. When the hydrophone is backbaffled, the hydrophone response for all azimuth angles beyond ±90° from broadside are zero. Broadside is defined as 0° azimuth and 0° elevation.

When the value of this property is false, the hydrophone is not backbaffled.

Methods

directivityDirectivity of isotropic hydrophone
isPolarizationCapablePolarization capability
patternPlot isotropic hydrophone directivity and patterns
patternAzimuthPlot isotropic hydrophone directivity and response patterns versus azimuth
patternElevationPlot isotropic hydrophone directivity and response patterns versus elevation
stepVoltage sensitivity of isotropic hydrophone
Common to All System Objects
clone

Create System object with same property values

getNumInputs

Expected number of inputs to a System object

getNumOutputs

Expected number of outputs of a System object

isLocked

Check locked states of a System object (logical)

release

Allow System object property value changes

Examples

expand all

Examine the response and patterns of an isotropic hydrophone operating between 1 kHz and 10 kHz.

Set up the hydophone parameters. Obtain the voltage sensitivity at five different elevation angles: -30°, -15°, 0°, 15° and 30°. All elevation angles are at 0&deg. The sensitivities are computed at the signal frequency of 2 kHz.

hydrophone = phased.IsotropicHydrophone('FrequencyRange',[1 10]*1e3);
fc = 2e3;
resp = hydrophone(fc,[0 0 0 0 0;-30 -15 0 15 30]);

Draw a 3-D plot of the voltage sensitivity.

pattern(hydrophone,fc,[-180:180],[-90:90],'CoordinateSystem','polar', ...
    'Type','powerdb')

Examine the response and patterns of an isotropic hydrophone at three different frequencies. The hydrophone operates between 1 kHz and 10 kHz. Specify the voltage sensitivity as a vector.

Set up the hydrophone parameters and obtain the voltage sensitivity at 45° azimuth and 30° elevation. Compute the sensitivities at the signal frequencies of 2, 5, and 7 kHz.

hydrophone = phased.IsotropicHydrophone('FrequencyRange',[1 10]*1e3, ...
    'VoltageSensitivity',[-100 -90 -100]);
fc = [2e3 5e3 7e3];
resp = hydrophone(fc,[45;30])
resp = 

   14.8051   29.2202   24.4152

Draw a 2-D plot of the voltage sensitivity as a function of azimuth.

pattern(hydrophone,fc,[-180:180],0,'CoordinateSystem','rectangular',...
    'Type','power')

Definitions

expand all

References

[1] Urick, R.J. Principles of Underwater Sound. 3rd Edition. New York: Peninsula Publishing, 1996.

[2] Sherman, C.S., and J.Butler. Transducers and Arrays for Underwater Sound. New York: Springer, 2007.

[3] Allen, J.B., and D. Berkely. “Image method for efficiently simulating small-room acoustics”, Journal of the Acoustical Society of America. Vol. 65, No. 4. April 1979, , pp. 943–950.

[4] Van Trees, H. Optimum Array Processing. New York: Wiley-Interscience, 2002, pp. 274–304.

Extended Capabilities

Introduced in R2017a

Was this topic helpful?