IGBT Loss Characteristics

This example shows how to use Simscape™ Electronics™ detailed switching device models to create tabulated switching loss data. This tabulated data can then be used with the switched linear Simscape™ Power Systems™ switching device component models to predict total losses in system models configured for fast and/or fixed-step simulation.

Model

Simulation Results from Simscape Logging

The plots below show the turn-on and turn-off switching losses as a function of load current for a range of device temperatures.