Three-Phase Programmable Voltage Source
Implement three-phase voltage source with programmable time variation of amplitude, phase, frequency, and harmonics
Library
Simscape / Electrical / Specialized Power Systems / Sources
Description
Use this block to generate a three-phase sinusoidal voltage with time-varying parameters. You can program the time variation for the amplitude, phase, or frequency of the fundamental component of the source. In addition, two harmonics can be programmed and superimposed on the fundamental signal.
Parameters
Parameters Tab
- Positive-sequence
The amplitude in volts RMS phase-to-phase, the phase in degrees, and the frequency in hertz of the positive-sequence component of the three voltages. Default is
[100 0 60]
.Phase B and phase C internal voltages lag phase A by 120 degrees and 240 degrees, respectively ([0 -120 +120]).
- Time variation of
Specify the parameter for which you want to program the time variation. Select
None
(default) if you do not want to program the time variation of the source parameters. SelectAmplitude
if you want to program the time variation of the amplitude. SelectPhase
if you want to program the time variation of the phase. SelectFrequency
if you want to program the time variation of the frequency.The time variation applies to the three phases of the source except when the Type of variation parameter is set to
Table of amplitude-pairs
. In that case you can apply a variation to phase A only.- Type of variation
Specify the type of variation that is applied to the parameter specified by the Time variation of parameter. Select
Step
to program a step variation. SelectRamp
to program a ramp variation. SelectModulation
to program a modulated variation. SelectTable of amplitude-pairs
to program a series of step changes of amplitudes at specific times.The
Table of amplitude-pairs
option is available only when the Time variation of parameter is set toAmplitude
.Table of amplitude-pairs
is the default when Time variation of is set toAmplitude
.Step
is the default when Time variation of is set toPhase
orFrequency
.- Variation on phase A only
If selected, the programmed time variation of the amplitude is applied only to phase A of the Three-Phase Programmable Voltage Source block. Default is cleared.
This parameter is enabled only when the Time variation of parameter is set to
Amplitude
and the Type of variation parameter is set toTable of amplitude-pairs
pairs.- Amplitude values (pu)
Specifies the amplitude variation points taken by the voltage source during the simulation. The specified values are in pu, based on the positive-sequence amplitude of the voltage source. The corresponding times where the variation will take place are defined by the Time values parameter. Default is
[1 0.8 1.2 1.0]
.This parameter is enabled only when the Time variation of parameter is set to
Amplitude
and the Type of variation parameter is set toTable of amplitude-pairs
.- Time values
Specifies the transition times, in seconds, of the amplitude variation defined in the Amplitude values (pu) parameter. Default is
[0 0.1 0.15 0.2]
.This parameter is enabled only when the Time variation of parameter is set to
Amplitude
and the Type of variation parameter is set toTable of amplitude-pairs
.- Step magnitude
This parameter is enabled only if the Type of variation parameter is set to
Step
.Specify the amplitude of the step change. The variation of amplitude is specified in pu of the positive-sequence amplitude. Default is
0.5
.- Rate of change
This parameter is enabled only if the Type of variation parameter is set to
Ramp
.Specify the rate of change, in volt/seconds. The rate of change of voltage is specified in (pu of the positive-sequence voltage)/second. Default is
10
.- Amplitude of the modulation
This parameter is only enabled if the Type of variation parameter is set to
Modulation
.Specify the amplitude of the modulation for the source parameter that is specified in the Time variation of parameter. When the varying quantity is the voltage amplitude, the amplitude of the modulation is specified in pu of the positive-sequence amplitude. Default is
0.3
.- Frequency of the modulation
This parameter is only enabled if the Type of variation parameter is set to
Modulation
.Specify the frequency of the modulation for the source parameter specified in the Time variation of parameter. Default is
2
.- Variation timing (s)
Specify the time, in seconds, when the programmed time variation takes effect and the time when it stops. Default is
[1 2]
.- Fundamental and/or Harmonic generation
If selected, two harmonics can be programmed to be superimposed on the fundamental voltage of the source. Default is cleared.
- A: [Order Amplitude Phase Seq]
This parameter is only enabled if the Fundamental and/or Harmonic generation check box is selected.
Specify the order, amplitude, phase, and the type of sequence (1 = positive-sequence; 2 = negative-sequence; 0 = zero-sequence) of the first harmonic to be superimposed on the fundamental signal. The voltage of the harmonic is specified in pu of the positive-sequence voltage. Default is
[3 0.2 -25 0]
.Specify
1
for the harmonic order and0
or2
for the sequence to produce a voltage imbalance without harmonics.- B: [Order Amplitude Phase Seq]
This parameter is only enabled if the Fundamental and/or Harmonic generation check box is selected.
Specify the order, amplitude, phase, and the type of sequence (0 = zero sequence, 1 = positive sequence, 2 = negative sequence) of the second harmonic to be superimposed on the fundamental signal. The voltage of the harmonic is specified in pu of the positive-sequence voltage. Default is
[2 0.15 35 2]
.Specify
1
for the harmonic order and0
or2
for the sequence to produce a voltage unbalance without harmonics.- Timing (s)
This parameter is enabled only if the Fundamental and/or Harmonic generation check box is selected.
Specify the time, in seconds, when the harmonic generation is superimposed on the fundamental signal and the time when it stops. Default is
[0.05 3]
.
Load Flow Tab
The load flow parameters are used to define block parameters for use with the Load Flow tool of the Powergui block. These load flow parameters are used for model initialization only. They have no impact on the block model and on the simulation’s performance.
The configuration of the Load Flow tab depends on the option selected for the Generator type parameter.
- Generator type
Specify the generator type of the voltage source.
Select
swing
(default) to implement a generator controlling magnitude and phase angle of its terminal voltage. The reference voltage magnitude and angle are specified by the Swing bus or PV bus voltage and Swing bus voltage angle parameters of the Load Flow Bus block connected to the voltage source terminals.Select
PV
to implement a generator controlling its output active power P and voltage magnitude V. P is specified by the Active power generation P parameter of the block. V is specified by the Swing bus or PV bus voltage parameter of the Load Flow Bus block connected to the voltage source terminals. You can control the minimum and maximum reactive power generated by the block by using the Minimum reactive power Qmin and Maximum reactive power Qmax parameters.Select
PQ
to implement a generator controlling its output active power P and reactive power Q. P and Q are specified by the Active power generation P and Reactive power generation Q parameters of the block, respectively.- Active power generation P
Specify the active power that you want generated by the source, in watts. Default is
0
. This parameter is available if you specify Generator type asPV
orPQ
.- Reactive power generation Q
Specify the reactive power that you want generated by the source, in vars. Default is
0
. This parameter is available only if you specify Generator type asPQ
.- Minimum reactive power Qmin
This parameter is enabled only if you specify Generator type as
PV
. Indicates the minimum reactive power that can be generated by the source while keeping the terminal voltage at its reference value. This reference voltage is specified in the Swing bus or PV bus voltage parameter of the Load Flow Bus block connected to the source terminals. The default value is-inf
, which means that there is no lower limit on the reactive power output.- Maximum reactive power Qmax
This parameter is enabled only if you specify Generator type as
PV
. Indicates the maximum reactive power that can be generated by the source while keeping the terminal voltage at its reference value. This reference voltage is specified in the Swing bus or PV bus voltage parameter of the Load Flow Bus block connected to the source terminals. The default value isinf
, which means that there is no upper limit on the reactive power output.
Example
The power_3phsignalseq
circuit
illustrates the use of the Three-Phase Programmable Voltage Source
block to produce a step variation of the positive-sequence voltage
and to inject harmonics into the circuit.
A 25 kV, 100 MVA short-circuit level, equivalent network feeds a 5 MW, 2 Mvar capacitive load. The internal voltage of the source is controlled by the Discrete 3-phase Programmable Voltage Source block.
A positive sequence of 1.0 pu, 0 degrees is specified for the fundamental signal. At t = 0.05 s a step of 0.5 pu is applied to the positive-sequence voltage magnitude, then at t = 0.1 s, 0.08 pu of fifth harmonic in negative sequence is added to the 1.5 pu voltage.
The three-phase voltage and current are measured at the output of the source impedance. Two Discrete Sequence Analyzer blocks are used to measure the positive-sequence fundamental component and the negative-sequence fifth harmonic of the three-phase voltage.