Three-Phase Series RLC Branch
Implement three-phase series RLC branch
Library
Simscape / Electrical / Specialized Power Systems / Passives
Description
The Three-Phase Series RLC Branch block implements three balanced branches consisting each of a resistor, an inductor, or a capacitor or a series combination of these. Use the Branch type parameter to select elements you want to include in each branch.
Negative values are allowed for resistance, inductance, and capacitance.
Parameters
- Branch Type
Select the elements you want to include in the branch. The R letter defines the resistor, the L letter defines the inductor, and the C letter defines the capacitor. Select Open circuit to define an open circuit (R=0, L=0, C=inf). Only existing elements are displayed in the block icon. Default is
RLC
.- Resistance R
The branch resistances, in ohms (Ω). Default is
1
.- Inductance L
The branch inductances, in henries (H). Default is
1e-3
.- Capacitance C
The branch capacitances, in farads (F). Default is
1e-6
.- Measurements
Select
Branch voltages
to measure the three voltages across the Three-Phase Series RLC Branch block terminals.Select
Branch currents
to measure the three currents flowing through the Three-Phase Series RLC Branch block.Select
Branch voltages and currents
to measure the three voltages and the three currents of the Three-Phase Series RLC Branch block.Default is
None
.Place a Multimeter block in your model to display the selected measurements during the simulation. In the Available Measurements list box of the Multimeter block, the measurements are identified by a label followed by the block name.
Measurement
Label
Branch voltages
Ua:
Branch currents
Ia:
See Also
Multimeter, Three-Phase Parallel RLC Branch,Three-Phase Parallel RLC Load, Three-Phase Series RLC Load
Version History
Introduced before R2006a