Single-Phase Circuit Breaker

Single-pole single-throw circuit breaker

Library

Switches & Breakers / Fundamental Components

Description

The Single-Phase Circuit Breaker block models a single-phase circuit breaker that uses an external signal and phase current information to break an electrical circuit.

The table shows how the external signal vT controls the block behavior.

ConditionBlock BehaviorResistance Parameter Used
vT < ThresholdThe breaker is closed. Port 1 connects to port 2.Closed Resistance
vT Threshold

When the current in port 1 goes through zero, the phase disconnects from port 2. The breaker is open.

Open Conductance


Parameters

Closed resistance

Resistance between ports 1 and 2 when the breaker is closed. The default value is 0.001 Ohm.

Open conductance

Conductance between ports 1 and 2 when the breaker is open. The default value is 1e-6 1/Ohm.

Threshold

Threshold voltage for the control port vT. The block uses the threshold voltage and the value of vT at the start of the simulation to determine whether the breaker is initially open or closed. When the voltage rises above the threshold, the breaker opens. When the control port voltage falls below the threshold, the breaker closes. The default value is 0 V.

Ports

The block has the following ports:

1

Electrical conserving port

2

Electrical conserving port

vT

Scalar control port, which is either a physical signal or an electrical port.

Introduced in R2013b