db_0125: Scope of internal signals and local auxiliary variables

ID: Title

db_0125: Scope of internal signals and local auxiliary variables

Priority

Strongly recommended

Scope

MAAB

MATLAB Versions

All

Prerequisites

None

Description

Internal signals and local auxiliary variables are "Local data" in Stateflow®:

  • All local data of a Stateflow block must be defined on the chart level or below the Object Hierarchy.

  • No local variables may exist on the machine level (that is, no interaction should occur between local data in different charts).

  • Parameters and constants are allowed at the machine level.

Correct

Incorrect

Rationale

  • Readability

  • Code Generation

Last Changed

V2.0

Model Advisor Check

By Task > Modeling Standards for MAAB > Stateflow > Check Stateflow data objects with local scope

For check details, see Check Stateflow data objects with local scope (Simulink Verification and Validation).