jc_0021: Model diagnostic settings

ID: Title

jc_0021: Model diagnostic settings

Priority

Strongly recommended

Scope

MAAB

MATLAB Versions

All

Prerequisites

None

Description

The following diagnostics must be enabled. An enabled diagnostic is set to warning or error. Setting the diagnostic option to none is not permitted. Diagnostics that are not listed may be set to any value (none, warning, or error).

Solver Diagnostics

  • Algebraic loop

  • Minimize algebraic loop

Sample Time Diagnostics

  • Multitask rate transition

Data Validity Diagnostics

  • Inf or NaN block output

  • Duplicate data store names

Connectivity

  • Unconnected block input ports

  • Unconnected block output ports

  • Unconnected line

  • Unspecified bus object at root Outport block

  • Mux blocks used to create bus signals

  • Invalid function-call connection

  • Element name mismatch

Rationale

  • Workflow

  • Code Generation

Last Changed

V2.0

Model Advisor Check

By Task > Modeling Standards for MAAB > Model Configuration Options > Check model diagnostic settings

For check details, see Check model diagnostic parameters (Simulink Verification and Validation).

Introduced in R2010a

Was this topic helpful?