Skip to Main Content Skip to Search
Product Documentation

C2000 Clarke Transformation - Convert balanced three-phase quantities to balanced two-phase quadrature quantities

Library

Embedded Coder/ Embedded Targets/ Processors/ Texas Instruments C2000/ Optimization/ C28x DMC

Description

This block converts balanced three-phase quantities into balanced two-phase quadrature quantities. The transformation implements these equations

and is illustrated in the following figure.

The inputs to this block are the phase a (As) and phase b (Bs) components of the balanced three-phase quantities and the outputs are the direct axis (Alpha) component and the quadrature axis (Beta) of the transformed signal.

The instantaneous outputs are defined by the following equations and are shown in the following figure:

The variables used in the preceding equations and figures correspond to the variables on the block as shown in the following table:

 Equation VariablesBlock Variables
InputsiaAs
 ibBs
OutputsidAlpha
 iqBeta

Dialog Box

References

For detailed information on the DMC library, see C/F 28xx Digital Motor Control Library, Literature Number SPRC080, available at the Texas Instruments Web site.

See Also

C2000 Inverse Park Transformation, C2000 Park Transformation, C2000 PID Controller, C2000 Space Vector Generator, C2000 Speed Measurement

  


Related Products & Applications

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.