| Contents | Index |
Logic and Bit Operations
The Detect Rise Positive block determines if the input is strictly positive, and its previous value was nonpositive.
The output is true (equal to 1) when the input signal is greater than zero, and the previous value was less than or equal to zero.
The output is false (equal to 0) when the input is negative or zero, or if the input is positive, the previous value was also positive.
The Detect Rise Positive block accepts signals of the following data types:
Floating point
Built-in integer
Fixed point
Boolean
For more information, see Data Types Supported by Simulink in the Simulink documentation.

Set the initial condition of the Boolean expression U/z > 0.
Specify whether the block performs sample- or frame-based processing. You can select one of the following options:
Elements as channels (sample based) — Treat each element of the input as a separate channel (sample-based processing).
Columns as channels (frame based) — Treat each column of the input as a separate channel (frame-based processing).
Note Frame-based processing requires a DSP System Toolbox license. For more information, see Sample- and Frame-Based Concepts in the DSP System Toolbox documentation. |
Inherited — Inherit the processing mode from the input signal and delay the input accordingly. You can identify whether the input signal is sample or frame based by looking at the signal line. Simulink represents sample-based signals with a single line and frame-based signals with a double line.
Use Input processing to specify whether the block performs sample- or frame-based processing. The block accepts frame-based signals for the input u. All other input signals must be sample based.
| Input Signal u | Input Processing Mode | Block Works? |
|---|---|---|
| Sample based | Sample based | Yes |
| Frame based | No, produces an error | |
| Sample based | Frame based | Yes |
| Frame based | Yes | |
| Sample based | Inherited | Yes |
| Frame based | Yes |
For more information about these two processing modes, see Sample- and Frame-Based Concepts in the DSP System Toolbox documentation.
Set the output data type to uint8 or boolean.
Direct Feedthrough | Yes |
Scalar Expansion | Yes |
Detect Change, Detect Decrease, Detect Fall Negative, Detect Fall Nonpositive, Detect Increase, Detect Rise Nonnegative