| Contents | Index |
ns
Default: 2
Specify the number of nanoseconds during which the model's data input signals and forced reset input signals are held past the clock rising edge.
The hold time is expressed as a positive integer or double (with a maximum of 6 significant digits after the decimal point).
This option applies to reset input signals only if forced resets are enabled.
The hold time is the amount of time that reset input signals and input data are held past the clock rising edge. The following figures show the application of a hold time (thold) for reset and data input signals when the signals are forced to active high and active low.
Hold Time for Reset Input Signals

Hold Time for Data Input Signals

ClockHighTime, ClockLowTime, ForceClock