| Contents | Index |
xPC Target Library for Advantech
Hardware Output | Block Input Data Type | Scaling |
|---|---|---|
TTL | Double | <0.5 = TTL low |
Enter channels between 1 and 16. This driver allows the selection of individual digital output lines in any order. The number of elements defines the number of digital lines you use.
For example, to use the first eight digital outputs, enter
[1,2,3,4,5,6,7,8]
Number the lines beginning with 1 even if the board manufacturer starts numbering the lines with 0.
Enter a base sample time or a multiple of the base sample time.
Enter the base address of the board. This entry must correspond to the DIP switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
0x300

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.
| © 1984-2012- The MathWorks, Inc. - Site Help - Patents - Trademarks - Privacy Policy - Preventing Piracy - RSS |