| Contents | Index |
xPC Target Library for Contec
Hardware Output | Block Input Data Type | Scaling |
|---|---|---|
Volts | Double | 1 |
From the list, select -5V to +5V, -10V to +10V, or 0 to +10V as the output range for the analog output. This range must correspond to the output range determined by the jumpers on the board.
This check box controls the behavior of the output channel at model termination. If the check box is selected, the output channel is reset to the value specified as the initial value. If the check box is not selected, the output channel remains at the most recent value attained while the model was running.
Enter the initial voltage value for the output channel. The output channel is set to this value between the time the model is downloaded and the time the model is started. Also, if the reset check box is selected, the output channel is reset to the initial value when the model is stopped.
Enter the base sample time or a multiple of the base sample time.
If only one board of this type is in the target PC, enter
-1
to automatically locate the board.
If two or more boards of this type are in the target PC, enter the bus number and the PCI slot number of the board associated with this driver block. Use the format [BusNumber, SlotNumber]. To determine the bus number and the PCI slot number, type
getxpcpci
Note that the Device ID of this board is 8123.