xPC Target Library for Contec
Hardware Output | Block Input Data Type | Scaling |
|---|---|---|
TTL | Double (Format:32 1-bit Channels) uint32 (Format:Single 32-bit Port) | Double: >0.5
= TTL high uint32: Bit set = TTL high |
From the list, select either
32 1-bit Channels — Indicates that the channel vector specifies the configuration of the block. Each output is a double with value of 0 or 1. The value is 0 when the hardware input voltage is low.
With this mode, the block reads, modifies, then writes the data. This enables you to use multiple instances of this block, with each block addressing a different bit. However, for efficiency, use a single block for each 32-bit group. Use multiple block instances only if your application requires multiple accesses.
Single 32-bit Port — Indicates that the output from the block is a 32-bit integer where all 32 bits on the board feed into the single output. The least significant bit is the lowest numbered bit in the Contec user manual.
If you choose this mode, use the bit packing and unpacking blocks (Digital I/O Bit-Packing and Digital I/O Bit-Unpacking) to construct the required data frames.
From the list, select either
A (Bits 0-31) — Selects the 32-bit word from Group A to address.
B (Bits 32-63) — Selects the 32-bit word from Group B to address.
(32 1-bit Channels mode only) Enter a vector of numbers to specify the output channels. For example, to use the first and third digital output channels, enter
[1, 3]
This vector indexes into group A or B channels. For group A, channel vector [1, 3] specifies channels 0 and 2. For group B, channel vector [1, 3] specifies channels 32 and 34.
The channel numbers can occur in any order, but the numbers must be in the range 1 to 32.
The initial value vector contains the initial voltage values for the output channels. Enter a scalar or a vector that is the same length as the channel vector. If you specify a scalar value, that value is the initial value for all channels. The channels are set to the initial values between the time the model is downloaded and the time it is started.
The final action vector controls the behavior of the channel at model termination. Enter a scalar or a vector that is the same length as the channel vector. If you specify a scalar value, that setting is used for all channels. If you specify a value of 1, the corresponding channel is reset to the value specified in the initial value vector. If you specify a value of -1, the block sets the channel to the value specified in the Final value vector value for that channel. If you specify a value of 0, the channel remains at the last value attained while the model was running.
The final value vector contains the final value for each output channel. Enter a scalar or a vector that is the same length as the channel vector. If you specify a scalar value, that setting is used for all channels. If the Final action vector is -1, the block sets the channel to this value on model termination.
Enter the base sample time or a multiple of the base sample time.
If only one board of this type is in the target PC, enter
-1
to automatically locate the board.
If two or more boards of this type are in the target PC, enter the bus number and the PCI slot number of the board associated with this driver block. Use the format [BusNumber, SlotNumber]. To determine the bus number and the PCI slot number, type
getxpcpci