| Contents | Index |
xPC Target Library for Humusoft
Hardware Output | Block Input Data Type | Scaling |
|---|---|---|
Volts | Double | 1 |
This parameter is a combined channel vector and range vector. The number of elements defines the number of D/A channels used.
Enter a range code for each of the channels used. This driver allows a different range for each channel with a maximum of two channels.
The following table is a list of the ranges for this driver and the corresponding range codes.
Input Range (V) | Range Code |
|---|---|
-10 to +10 | -10 |
-5 to + 5 | -5 |
0 to +10 | 10 |
0 to +5 | 5 |
For example, if the first channel is -10 to +10 volts and the second channel is 0 to +5 volts, enter
[-10,5]
Enter the base sample time or a multiple of the base sample time.
Enter the base address of the board. This entry must correspond to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
0x300

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.