Skip to Main Content Skip to Search
Product Documentation

Humusoft AD 512 Digital Input - HUMUSOFT AD 512 Digital Input block

Library

xPC Target Library for Humusoft

Scaling Input to Output

Hardware Input

Block Output Data Type

Scaling

TTL

Double

TTL low = 0.0
TTL high = 1.0

Channel vector

Enter a numbers between 1 and 8. This driver allows the selection of individual digital line numbers in any order. The number of elements defines the number of digital input lines used.

For example, to use the first, second, and fifth digital input lines, enter

[1,2,5]

Number the lines beginning with 1, even if the board manufacturer starts numbering the lines with 0.

Sample time

Enter the base sample time or a multiple of the base sample time.

Base address

Enter the base address of the board. This entry must correspond to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter

0x300
  


Related Products & Applications

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.

 © 1984-2012- The MathWorks, Inc.    -   Site Help   -   Patents   -   Trademarks   -   Privacy Policy   -   Preventing Piracy   -   RSS