| Contents | Index |
xPC Target Library for Humusoft
Hardware Output | Block Input Data Type | Scaling |
|---|---|---|
TTL | Double | < 0.5 = TTL low |
Enter numbers between 1 and 8. This driver allows the selection of individual digital line numbers in any order. The number of elements defines the number of digital output lines used.
For example, to use the first, second, and fifth digital output lines, enter
[1,2,5]
Number the lines beginning with 1, even if the board manufacturer starts numbering the lines with 0.
Enter the base sample time or a multiple of the base sample time.
Enter the base address of the board. This entry must correspond to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
0x300