| Contents | Index |
xPC Target Library for Parallel Port
Hardware Input | Block Output Data Type | Scaling |
|---|---|---|
TTL | Double (Format:5 1-bit Channels) | Double: TTL
high = 1.0 |
uint8 (Format:One 5-bit Port) | uint8: TTL high corresponding bit is set |
Select a parallel port base address. This address depends on the PC BIOS. From the list, select one of the following. If your base address is not one of the supplied standard base addresses, select Other and enter your base address in Alternate base address.
0x3bc
0x378
ox278
Other
Enter an alternate parallel port base address, in hexadecimal. This parameter appears only if you select Other for Base address. For example,
0x300
From the list, select one of the following modes to specify how to treat data:
5 1–bit Channels
Treats data as individual bits. Configures block to accept up to five 1-bit channels.
One 5–bit Port
Treats data as a single byte. Configures block to accept one 5-bit port.
Enter a vector of numbers between 1 and 5. This parameter appears only if you select 5 1–bit Channels for Format. For example,
[1, 3]
Enter the base sample time or a multiple of the base sample time.

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.