| Contents | Index |
xPC Target Library for Real Time Devices
You can use only one digital input block per port. You can use an input and an output block for the same port, but then each block must use channels different from those in the other block.
Hardware Input | Block Output Data Type | Scaling |
|---|---|---|
TTL | Double | TTL low = 0.0 |
Enter numbers between 1 and 8 to select the digital input lines used with this port. This driver allows the selection of individual digital input lines in any order. The number of elements defines the number of digital lines used.
For example, to use all the digital inputs for the current port, enter
[1,2,3,4,5,6,7,8]
Number the lines beginning with 1 even if the board manufacturer starts numbering the lines with 0.
Select port A, B, or C.
Enter a base sample time or a multiple of the base sample time.
Enter the base address of the board. This entry must correspond to the base address board setting. For example, if the base address is 300 (hexadecimal), enter
0x300