Skip to Main Content Skip to Search
Product Documentation

RS-232/422/485 Filter Interrupt Reason (Composite) - RS-232/422/485 Filter Interrupt Reason block

Library

xPC Target Library for RS232

Description

The Filter Interrupt Reason block filters the output of the Read Int(errupt) Status block. If the condition that the interrupt query block reads from the IIR register matches the one chosen here, the output is true.

This block is used exclusively inside the interrupt service subsystem for this board.

Block Parameters

Port

From the list, choose a port. This parameter specifies the port from which this block gets control data.

Filter value

From the list, choose Receive data, Transmitter empty, or Modem status change. This parameter specifies the interrupt reason that this filter block is looking for.

Note that Modem status change currently has no effect because the interrupt is never enabled.

  


Related Products & Applications

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.

 © 1984-2012- The MathWorks, Inc.    -   Site Help   -   Patents   -   Trademarks   -   Privacy Policy   -   Preventing Piracy   -   RSS