Skip to Main Content Skip to Search
Product Documentation

TI DM642 TX - TI DM642 transmit block

Library

xPC Target Library for Texas Instruments

Block Parameters

Region

Enter a unique number (starting with 1) to identify the memory region for this block.

    Note   Region numbers must match the regions specified in the DM642 model.

Data type and size (cell array)

Enter a cell array of character strings and port widths, in the form of {'datatype[port width]'}, for each port. Valid data types are:

  • 'double'

  • 'single'

  • 'int8'

  • 'uint8'

  • 'int16'

  • 'uint16'

  • 'int32'

  • 'uint32'

  • 'boolean'

For example, a value of {'double[1]'} specifies a port data type of double and a width of 1.

Block until data has been read

Select this box to write data only after the device has read existing data. The block is in a busy wait state until the data has been read. Be careful to avoid deadlock situations when selecting this block.

Sample time

Model base sample time or a multiple of the base sample time.

PCI Slot (-1:autosearch)

If only one board of this type is in the target PC, enter

-1

to automatically locate the board.

If two or more boards of this type are in the target PC, enter the bus number and the PCI slot number of the board associated with this driver block. Use the format [BusNumber, SlotNumber]. To determine the bus number and the PCI slot number, type

getxpcpci
  


Related Products & Applications

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.

 © 1984-2012- The MathWorks, Inc.    -   Site Help   -   Patents   -   Trademarks   -   Privacy Policy   -   Preventing Piracy   -   RSS