| Contents | Index |
xPC Target Library for Versalogic
Hardware Input | Block Output Data Type | Scaling |
|---|---|---|
TTL | Double | TTL low = 0.0 |
Enter a numbers between 1 and 16 to select the number of digital input lines used. This driver allows the selection of individual digital input lines in any order. Each group of eight lines (1 to 8 or 9 to 16) can be only input or output. For example, if any bit in the range 1 to 8 is an input line, lines 1 to 8 must be input lines.
For example, to use the first, second and fifth digital input lines, enter
[1,2,5]
Number the lines beginning with 1, even if the board manufacturer starts numbering the lines with 0.
Enter the base sample time or a multiple of the base sample time.

Learn more about Simulink through this collection of videos, articles, technical literature and the Getting Started with Simulink Guide.