Diamond Ruby-MM-416 Digital Output

Ruby-MM-416 Digital Output block


Simulink® Real-Time™ Library for Diamond


Ruby-MM-416 boards have three I/O ports, each containing eight digital I/O lines. These ports can be configured independently for either input or output. Use a separate driver block for each port. By selecting the digital input driver block for a given port, that port is configured for input.

Scaling Input to Output

I/O Module Input

Block Output Data Type




TTL low = 0.0
TTL high = 1.0

Block Parameters

Channel vector

Enter numbers between 1 and 8 to select the digital output lines used with this port. This driver allows the selection of individual digital output lines in arbitrary order. The number of elements defines the number of digital lines used.

For example, to use all the digital outputs for the current port, enter


Number the lines beginning with 1 even if this board manufacturer starts numbering the lines with 0.


From the list choose A, B, or C.

Sample time

Enter the base sample time or a multiple of the base sample time (-1 means sample time is inherited).

Base address

Enter the base address of the board. This entry must correspond to the DIP switch setting on the board. For example, if the DIP switch setting is 300 (hexadecimal), enter 0x300.

Was this topic helpful?