Humusoft AD 512 Analog Output (D/A)

HUMUSOFT AD 512 Analog Output block (not recommended)


Simulink® Real-Time™ Library of Drivers No Longer Recommended for Use

Scaling Input to Output

Hardware Output

Block Input Data Type





Block Parameters

Channel vector

This parameter is a combined channel vector and range vector. The number of elements defines the number of D/A channels used.

Enter a range code for each of the channels used. This driver allows a different range for each channel with a maximum of two channels.

The following table is a list of the ranges for this driver and the corresponding range codes.

Input Range (V)

Range Code

-10 to +10


-5 to + 5


0 to +10


0 to +5


For example, if the first channel is -10 to +10 volts and the second channel is 0 to +5 volts, enter

Sample time

Enter the base sample time or a multiple of the base sample time (-1 means sample time is inherited).

Base address

Enter the base address of the board. This entry must correspond to the DIP switch setting on the board. For example, if the DIP switch setting is 300 (hexadecimal), enter 0x300.

Was this topic helpful?