Documentation

IEEE 1588 Sync Status

Output synchronization status of Precision Time Protocol

  • Library:
  • IEEE 1588

Description

When the absolute value of the offset from the master PTP clock is less than or equal to the threshold, the output port value is true. If the node is selected as the master clock, the output port value becomes true when it enters the MASTER state.

Ports

Output Arguments

expand all

When the absolute value of the offset from the master PTP clock is less than or equal to the specified threshold, returns true.

Parameters

expand all

Threshold value, in seconds, from which the node is considered well synchronized to the master PTP clock node. The default value is 10 μs. The minimum allowed value is 1 μs.

Enter the base sample time or a multiple of the base sample time.

Introduced in R2015b

Was this topic helpful?