How to specify tolerance using linsolve ?
4 views (last 30 days)
Show older comments
Hi,
I have a linear system that I want to solve with Matlab using linsolve. My problem is that the coefficients' range of the system is huge. The minimum coefficient start at e-20 while the max reach 10e25. When I use linsolve, I get a warning telling me "Warning: Rank deficient, rank = 15, tol = 5.2711e+005.". When I use rank on my system, I effectively observe that my system is not full rank. But when I use rank(sys, tol) with a small tol value (~e-15), I obtain a full rank system.
So I suppose that linsolve choose a tolerance that is to high for my system and my question is if there exists a way to specify a tolerance value to linsolve in ordre to solve system with a high range of coefficients.
Thanks
0 Comments
Accepted Answer
pietro
on 16 Nov 2014
It is strongly suggested to normalize your design variables, contraints and so on in order to have a similar variation of the gradient and lagragian functions. Please post your problem and I will help you
3 Comments
pietro
on 16 Nov 2014
well the design variables may be scaled in this way:
(x-lb)./(ub-lb)
where x is the array with the design variables, ub the array with upper bounds and lb is the array with lower bounds
More Answers (0)