DC/DC and DC/AC PWM Converters result problem

5 views (last 30 days)
Hello sir.
I simulated demo model of simpowersystem.
Title is DC/DC and DC/AC PWM Converters
But It's something strange.
In first model Buck-boost converter. The duty is 0.8 in Pulse block properties
But Pulse block output is 0.9 duty ratio. It control half bridge.
Why is it different, If duty is 0.8, Output is 320V
Please check it.

Answers (2)

Purushottama Rao
Purushottama Rao on 13 May 2015
If duty is 0.8, the output was 359V.
If duty is 0.9, the output was 379V. pls see the attached results
  2 Comments
Purushottama Rao
Purushottama Rao on 13 May 2015
That demo modelis giving the expected results.
Hyounglok Oh
Hyounglok Oh on 13 May 2015
Thank you for your analysis.
DId you see PWM wave? Please check duty of PWM wave again. ( Like Below figure )
I checked the model, It set 80% ( Modulation index).
But PWM duty is 90% Final and current average is 160A
then duty modify to 80% the current average is 120A

Sign in to comment.


Purushottama Rao
Purushottama Rao on 13 May 2015
Yeah i do agree with your analysis. There is a mis understanding of the PWM pulse generation. In the model the carrier wave is generated between -1 to 1. By comparing with a constant value of 0.8 or 0.9, the expected output will not be 80% or 90%.
However if you want the duty ratio output as you expect, change the carrier wave to triangular wave between 0 and 1. Pls see the attached.
  1 Comment
Purushottama Rao
Purushottama Rao on 13 May 2015
Pls note that in this case, the given expression for Vout is not valiD if you change the carrier wave.
Now it will be m*Vin

Sign in to comment.

Communities

More Answers in the  Power Electronics Control

Categories

Find more on Electrical Block Libraries in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!