Simulink shows only the last 2 second of simulation time

Asked by Alzapoa on 9 Feb 2012
Latest activity Edited by Matt J on 6 Oct 2013

Hello,

My Simulink model of an induction machine run about 2 second even if the simulation time is 20 sec. any idea on that?

The model is include of 3-phase to d-q model and then transforming to rotor reference model. the last step is deriving currents and applying the electrical torque and the mechanical torque has not been implemented yet. sot machine is working in no-load condition.

Regards,

0 Comments

Alzapoa

Products

No products are associated with this question.

1 Answer

Answer by Andreas Goser on 9 Feb 2012
Accepted answer

Please verify the scope setting: Parameters - Data History - Limit Data Point to last.

The default is it is checked and limited to 5000 points.

1 Comment

Alzapoa on 9 Feb 2012

Thank you. Now it's ok!