how to design a low pass the filter, h1, cuttoff frequency=0.25 using a Kaiser window with suitable parameters (you have the liberty to choose the value of beta) to get a linear phase filter using fdatool. how to cater cutoff frequency in fdatool?
3 views (last 30 days)
Show older comments
What is Fc in fdatool. Whether it is cuttoff frequency wc. Fc is in Hz. while wc=.25pi. how to use .25pi for this design of filter.
0 Comments
Answers (1)
Honglei Chen
on 8 Oct 2013
To translate the angular frequency to nominal frequency, you just need to know that the sampling rate corresponds to 2*pi, so
wc = Fc/Fs*(2*pi)
0 Comments