How do I create an ideal transformer in SimPowerSystems?

10 views (last 30 days)
The documentation for the Linear Transformer block states that:
To implement an ideal transformer model,
set the winding resistances and inductances
to 0, and the magnetization resistance
and inductance to inf.
I try to create an ideal transformer in the demo model psbtransfo.mdl. However, if I set the parameters accordingly and run the model, I get the following error dialog box:
Error in block 'Linear Transformer 75kVA 14400-120-120V,
Parameter 'Rm' must have a finite value
and the following Simulink error:
Error evaluating 'InitFcn' callback of Voltage Measurement block (mask) 'PQ'. Error using ==> d:/matlab6p5/toolbox/powersys/powersys/private/blocinit (errorInf)
Parameter error

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 27 Jun 2009
This bug has been fixed for Release 14 (R14). For previous releases, read below for any possible workarounds:
This is an error in documentation in SimPowerSystems 2.3 (R13).
The documentation should read as follows:
To implement a quasi-ideal transformer model,
set the winding resistances and inductances to 0,
and the magnetization inductance Lm to inf.
The Rm value must have a finite value.
Use a large value such as 1e4.