What trigger modes are available for DCAM devices with the Image Acquisition Toolbox?

2 views (last 30 days)
The IIDC 1394-based Digital Camera (DCAM) Specificaiton describes four different triggering modes for DCAM comaptible cameras: Trigger Mode 0, 1, 2, and 3. I would like to know which are supported for DCAM devices with the Image Acquisition Toolbox.

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 19 May 2010
This enhancement has been incorporated in Release 2010a (R2010a). For previous product releases, read below for any possible workarounds:
The Image Acquisition Toolbox only supports DCAM trigger mode 0 which is supported by most DCAM compatible cameras. Trigger Modes 1, 2, and 3 are being considered for a future toolbox enhancement.
Trigger mode 0 begins image capture at the leading edge of an external trigger signal.