% RF Utilities V1.2
%
% Directories : RFutils & RFutils_S
%
% RFutils_M has its own contents file, accessed by
% typing: help rfutils_m
%
% Display routines
% smith - Smith chart.
% sadmit - Admittance chart.
% scomb - Smith / Admittance chart.
% smdrawc - Draw impedance on smith chart.
% smarker1 - Put markers on Smith charts.
% samarker1 - Put markers on Admittance charts.
% smcirc - Draw VSWR circle on smith chart.
%
% vswrc - Plot VSWR vs frequency
% vsdrawc - Add VSWR trace to an existing plot
% vmarker1 - Put markers on VSWR traces
%
% rlossc - Plot Return Loss vs frequency
% rldrawc - Add Return Loss trace to an existing plot
% rmarker1 - Put markers on Return Loss traces
%
% mlossc - Plot Mismatch Loss vs frequency
% mldrawc - Add Mismatch Loss trace to an existing plot
% mmarker1 - Put markers on Mismatch Loss traces
%
% ilossc - Plot Insertion Loss vs frequency
% ildrawc - Add Insertion Loss trace to an existing plot
% imarker1 - Put markers on Insertion Loss traces
%
% phdelayc - Plot Phase Delay vs frequency
% phdrawc - Add Phase Delay trace to an existing plot
% phmarker1 - Put markers on Phase Delay traces
%
% gdelayc - Plot Group Delay vs frequency
% gdrawc - Add Group Delay trace to an existing plot
% gmarker1 - Put markers on Group Delay traces
%
%
%
% Lumped element components
% trl - Transmission line model for lossy line
% rseries - Series resistance
% rshunt - Shunt resistance
% lseries - Series inductance
% lshunt - Shunt inductance
% cseries - Series capacitance
% cshunt - Shunt capacitance
% junct - Impedance junction
%
% Utilities
% tdr - Time Domain Reflectometry (impedance vs distance)
% citi1 - Load 1-port citi file as an input impedance
% citi1s - Load 1-port citi file as S-params
% citi2s - Load 2-port citi file as S-params
% s2z - Convert single S-param vector to impedance Z
% z2s - Convert single impedance vector Z to S-param
% s2mm - Convert standard S-param to mixed-mode S-params (4-port)
% loads2p - Load 2-port S2P files (as output by RFSim99)
% loadsonnet4 - Load 4-port S-parameter data (as output by Sonnet Lite)
% gslbl - Add leader and text label at point on chart selected by mouse
% gsmpt - Show impedance at points on Smith Chart selected by mouse
% textsc - Places text at screen coords on current figure
%
% Subroutines
% smsub1&2 }
% sasub1&2 } - Impedance chart subroutines
% scsub1&2 }
%
% Examples
% example1 - Transmission line matching example for smith.m
% example2 - Lumped element matching example for scomb.m
% example2a - Two-stub matching example using junct.m
% example3 - Transmission line matching example for vswr.m
% example4 - Cascaded Tx-Line filter example for rlossc.m and mlossc.m
% example5 - Use of the CITI file loader
%
% example6 - Time Domain Reflectometry, measuring line impdances
% example7 - Time Domain Reflectometry, lumped element discontinuities
% example8 - Plotting transmission parameters, imported from a CITI file
%
% example9 - Plotting impedances and transmission parameters imported
% from an S2P file exported from RFsim99
%
% example10 - Plotting differential impedances and TDR on differential lines.
% The source data is modelled and imported from Sonnet Lite
%
% example11 - Using the standard to mixed mode S-param function s2mm.m
% Plotting common mode impedances and TDR on differential lines.
% The source data is modelled and imported from Sonnet Lite
% N.Tucker www.activefrance.com 2008