function response = pumpobjcomm(type, serialObject, command)
% PUMPOBJCOMM Reads and writes data from Jasco pumps
% pumpobjcomm(type, serialObject, command) reads from or writes information
% to Jasco pumps connected via RS232 serial ports. type is 'read' or
% 'write', serialObject is the valid serial object and command the command
% to be sent (string). Automatically leaves a 0.15 s pause after any
% commands where there is no response expected to prevent communications
% issues.

% Normal usage:

% e.g. 1 pumpobjcomm('read', serialObject, 'a_flow load p') - returns the
% current flow rate from the pump on COM9.

% e.g. 2 pumpobjcomm('write', serialObject, '0.200 flowrate set') - sets the
% flow rate to 0.200 mLmin-1.

% Range:

% type = 'read' or 'write'

% serialObject = valid serial object

% command = string with maximum 4 parts


% error handling of arguments as arguments must be a number and in the
% correct range. Text can still be classed as an acceptable uint8/16 object
% so both logical decisions are necessary

% checks the number of arguments
error(nargchk(3, 3, nargin))

% pre-parses command for error checking
if nargin >= 3
    % splits it up into words
    commandParse = textscan(command, '%s');
end

% error checking here
if ~isequal(type, 'read') && ~isequal(type, 'write')
    % errors
    error('type must be "read" or "write".')
    
elseif ~isserial(serialObject) || (~isfield(serialObject.UserData, 'realTermHandle') && ~isrunning(serialObject))
    % the serial object must be valid and open to send or receive data
    % (unless there is a realterm handle available)
    error('serialObject must be a valid open serial object')
    
elseif ~isserial(serialObject) || (isfield(serialObject.UserData, 'realTermHandle') && ~isrunning(serialObject.UserData.realTermHandle))
    % if the handle is there, the object must be running (PortOpen is 1)
    error('If the Realterm handle is present, the object must be connected via Realterm.')
    
elseif isfield(serialObject.UserData, 'realTermHandle') && (~isfield(serialObject.UserData, 'captureFileID') || ~isfid(serialObject.UserData.captureFileID))
    % if using realterm, the capture file ID must be there
    error('If using Realterm, the capture file handle must be in the serial object''s UserData.')
    
elseif ~isstring(command) || length(commandParse{1}) > 4
    % Pump will ignore any additional spaces between the words so it is not
    % necessary to remove them if they are there
    error('command must a string with no more than 4 words.')
end

% flushes everything in the buffer
serialflush(serialObject);

% sends command
serialprint(serialObject, command, 'async')

% if reading data, expecting a response
if strcmp(type, 'read')
    % initialises loop
    response = '%%';

    % keeps on requesting a response until there is no '%%' in the
    % output - this cancels through any errors there may be
    while ~isempty(strfind(response, '%%'))
        % reads data
        response = serialscan(serialObject);

        % if the response was empty, error
        if isempty(response)
            % errors
            error(['No response from Jasco pump to "', command, '".'])

        else
            % strips off the terminators
            response = response(1:end - 2);
        end
    end
    
else
    % Must pause 150 ms after command before the next command is sent to
    % avoid issues with pump not processing commands quickly enough -
    % if a response has been retrieved then by definition its ready for
    % another command so this pause is ONLY required for writing data
    % when no response is given
    pause(0.15)
end