Code covered by the BSD License  

Highlights from
Hydraulic Valve Parameters From Data Sheets and Experimental Data

image thumbnail

Hydraulic Valve Parameters From Data Sheets and Experimental Data

by

 

16 Apr 2010 (Updated )

Models and white paper on obtaining realistic parameter values from data sheets and measured data.

plot_reference_data.m
% Script to plot manufacturer's frequency response characterstic
% (phase only)
% Copyright 2010, MathWorks Inc.

%% REFERENCE DATA, Eaton SM4-40 Servovalve
RefFR_100_Frq =     [7 10 20 30 40 43 50 54];
RefFR_100_Phs = -1*[25 35 59 75 87 90 96 100];

RefFR_40_Frq =     [7 10 20 30 40 50 57 70];
RefFR_40_Phs = -1*[21 30 50 63 75 85 90 100];

%% PLOT TO COMPARE WITH DATA SHEET
figure(2)
semilogx(RefFR_40_Frq,-RefFR_40_Phs,'k-','LineWidth',2.5);
hold on
semilogx(RefFR_100_Frq,-RefFR_100_Phs,'k--','LineWidth',2.5);
hold off
axis([3 200 10 100]);
grid on
title('Manufacturer''s Data (Phase)','FontSize',14);
xlabel('Frequency (Hz)','FontSize',12);
ylabel('Phase (deg)','FontSize',12);
legend({'+/-40% Rated Current','+/-100% Rated Current'},'Location','Best');