Code covered by the BSD License  

Highlights from
Hydraulic Valve Parameters From Data Sheets and Experimental Data

image thumbnail

Hydraulic Valve Parameters From Data Sheets and Experimental Data

by

 

16 Apr 2010 (Updated )

Models and white paper on obtaining realistic parameter values from data sheets and measured data.

find_actuator_param_pulse_FFT_method.m
% Script file to determine valve actuator parameters using FFTs
% Copyright 2010 MathWorks, Inc.

% This script file is designed to find three  parameters of the valve
% actuator: Gain, Time Constant, and Saturation, by computing frequency
% response of the actuator by applying the Fast Fourier Transform to the
% pulse transient response of the system. The script analyzes two pulse
% responses of the valve actuator. One corresponds to a 100% rated signal,
% while the other is a 20% of rated signal. The script invokes the
% optimization procedure which is set to find match between the required
% and actual frequency characteristics. The characteristics are compared by
% frequency at which phase shift in -90 deg takes place. After the
% optimization is completed, the check of the obtained parameters is
% performed either with the FFT or direct measurement method.

% Specifying required frequency at which -90 deg phase shift occurs
frequency_20 = 25;      % Frequency (Hz) at -90 deg shift angle and 20% input
frequency_100 = 10;     % Frequency (Hz) at -90 deg shift angle and 100% input

% Set initial value. x0 =[gain, time_const, saturation]
x0 = [300, 0.01, 0.8];

% Optimization
[x,fval,exitflag,output] = ...
    fminsearch(@obj_actuator_param_pulse_FFT_method,x0, ...
    optimset('Tolx',1e-6,'Display','iter'),frequency_20,frequency_100);

% Determine accuracy using FFT
check_frequency_response(x, frequency_20, frequency_100,'FFT');

%% Determine accuracy using direct method (time domain)
check_frequency_response(x, frequency_20, frequency_100, 'Direct');